Model: PCM-L04S100-J99 ver: A | ||
Test item(Test at normal temperature 25±2 ) | Criterion | |
Communication Interface | UART&Bluetooth | |
Voltage | Charging voltage | DC55.2V~67.2V CC/CV(3.45V~4.2V/Cell)16s |
Cell-balance detection voltage Charge balance | can be adjusted by required | |
Cell-balance detection delay time | 0.5S-2S | |
Supply Current | Balance current for single cell | 32-58mA |
Normal operating-mode current Gas Gauge IC | 600 uAaverage | |
SLEEP operating-mode current Gas Gauge IC | 350 uAaverage | |
Max continuous charging current | 30-100A | |
Max continuous discharging current | 30-100A | |
Over charge detection voltage | 3.65-4.35V | |
Over-charge Protection (single cell) |
Over charge detection delay time | 0.5S-2S |
Over charge release voltage | 3.4-4.15V | |
Over discharge protection (single cell) |
Over discharge detection voltage | 2.0-3.0V |
Over discharge detection delay time | 150-300mS | |
Over discharge release voltage | 2.3-3.2V | |
Current protection (Battery pack) |
Discharge Over current detection current | 60-300A |
Detection delay time | 50ms-300ms | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤65mΩ |
Temperature | Operating Temperature Range | -40°C~85°C |
Storage Temperature Range | -40°C~125°C | |