Battery Management System 18 years ODM/OEM factory 24s 200A for lithium-ion LiFePO4 battery with communication RS485&Canbus Bluetooth smart BMS
Model: AY-L24S200A-M093(RS485&CANbus&Bluetooth) | ||
Test item(Test at normal temperature 25±2ºC ) | Criterion | |
Voltage | Charging voltage | DC:57.6V CC/CV (3.6v/Cell)16S |
Supply Current | Current consume in sleep operation | ≤150uA |
Max continuous charging current | 150A | |
Max continuous discharging current | 150A | |
Current consume in normal operation | ≤25uA | |
Balanced | Balance voltage for single cell (Adjustable) | 3.4V±0.05V |
Turn on the pressure difference (Adjustable) | 20mV | |
Over-charge Protection (single cell) |
Over charge detection voltage | 3.65±0.05V |
Over charge detection delay time | 3.0S | |
Over charge release voltage | 3.45±0.05V | |
Over discharge protection (single cell) |
Over discharge detection voltage | 2.5±0.05V |
Over discharge detection delay time | 3.0S | |
Over discharge release voltage | 2.8±0.05V | |
Charge Over current protection |
ChargeOver current detection current | 150±3%A |
Detection delay time | 10S | |
Release conditions | Removing the load is lifted |
|
Short protection | Detection condition | External load short circuit |
Detection delay time | 400us | |
Release condition | Remove load | |
SOC | accuracy(It takes a charge-discharge cycle to achieve the accuracy requirement after initial power-on.) | 3%~5% |
Temperature | Operating Temperature Range | -20~+70ºC |
Storage Temperature Range | -40~+85ºC | |
SIZE: L216 *W100* T19 mm | ||
NTC:10K NTC*2sets Temperature switch:Yes Weak current switch:/ Activation Method:/ |