Type: | Li-ion Battery |
---|---|
Cathode Material: | NCM |
Rechargeable: | Yes |
Battery Management System Lithium LiFePO4 BMS 20s 50A 100A BMS for Lithium Battery with Temperature Protection BMS
Model: AY-L20S120A-M028(RS485&CANBUS) | ||
Test item(Test at normal temperature 25±2ºC ) | Criterion | |
Voltage | Charging voltage | DC:3.45V~4.2V CC/CV(3.45V~4.2V/Cell)1s |
Supply Current | Current consume in sleep operation | ≤200uA |
Max continuous charging current | 100A | |
Max continuous discharging current | 100A | |
Balance current for single cell | 36-42mA | |
Over-charge Protection (single cell) |
Balance voltage for single cell | 3.45-4.20V |
Over charge detection voltage | 3.65-4.35V(Adjust) | |
Over charge detection delay time | 0.5S-2S(Adjust) | |
Over charge release voltage | 3.45-4.15V(Adjust) | |
Over discharge protection (single cell) |
Over discharge detection voltage | 2.4-3.0V(Adjust) |
Over discharge detection delay time | 0.5-2S(Adjust) | |
Over discharge release voltage | 2.5-3.2V(Adjust) | |
Current protection (Battery pack) |
Discharge Over current detection current | 200A(Adjust) |
Detection delay time | 2s(Adjust) | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us(Adjust) | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤65mΩ |
Temperature | Operating Temperature Range | -40~+85ºC |
Storage Temperature Range | -40~+125ºC | |
SIZE: L165*W100*T18mm | ||
NTC:/ Temperature switch:/ Weak current switch:/ Activation Method:/ |